3-6
Refer to Figure [3-6]. The manual backup pump is used to operate the lift if there is no electrical
power (the manual backup pump is shown within the standard pump enclosure). The controls
for the pump consist of the pump handle extension (installed by the vehicle manufacturer near
the pump or stored within the optional pump enclosure cover) for raising the lift platform and the
pump release valve for lowering.
FIGURE [3-6]: STANDARD PUMP ENCLOSURE
a. To Raise Platform Manually
Refer to Figure [3-7]. To raise the platform manually, insert the pump handle extension onto
the pump release valve. Make sure the notches at the end of the handle are fully engaged
by the release valve pin. Twist the handle CLOCKWISE until lightly-snug to make sure that
the pump is in the “raise mode”. Insert the handle extension into pump handle socket and
move the handle extension UP and DOWN to raise the platform.
FIGURE [3-7]: PLATFORM MANUAL RAISING